Setup B&R project
Prerequisites | UP - Getting started: Setup project with wizard |
Goal | Running B&R PLC project |
Topics covered | Create a B&R project |
Target Project
- Go to the Automation Studio and create a new project
- Enter name: FirstSteps
- Press Next
- Consider that B&R project must located at B&R target folder at swiss.avm.up.doc.tutorial.first. Use one of multiple approaches for that:
- Rename target folder created by UP: up-gen_BR to FirstSteps. Name of B&R Project must be equal to folder name, since B&R Automation Studio creates a sub folder automatically. Name with '-' not supported by B&R Automation Studio.
- Delete up-gen_BR and create a new Folder, use Advanced mode, Link to alternate location (Browse project folder created by B&R Automation Studio), for further details contact Create linked target folder.
- Delete up-gen_BR folder outside of UPstudio (File Explorer). Create a symlink up-gen_BR to created Project folder from B&R Automation Studio.
- Name of the configuration: Simulation
- Press Next
- Select Standard PC
- Select PC
- Press Finish
- Force Generate Code
- The code is being generated
- To solve the display problems (some folder are not displayed correctly), the Automation Studio should be closed and reopened.
- Compile and start the application
Congratulation, you have finished the tutorial!
Next step: